The semi-automatic electrochemical copying-broaching device Description and Specifications for Lab Tenders
The semi-automatic electrochemical copying-broaching device.
The semi-automatic electrochemical copying-broaching device
The semi-automatic electrochemical copying-broaching device is designed
for shapig in the work parts from structural, instrumental,
corrosion-proof, heat-resistant, magnetic steels and alloys.
• Table operational surface size, mm -300x200
• Operational chamber size, mm -700x440x600
• Distance between the table operational surface and electrode holder
end, mm -100
• Table movement, mm:- 200
• Processing area, sq. mm: -4200
• Processing output, cu. mm/min:- 1200
• Electrode copying accuracy, mm, in the range: +0.01
• Table feed rate, mm/min, operational:0.01-9.99
• -"-accelerated:340
• Electrode tool vibration frequency, Hz:50
• Electrode tool vibration magnitude, Hz - 0.32
• Electrolyte feeding pump, type: vortex
• Output, m/hour (l/min):5.1 (85)
• Head, nominal, mPa (kg/cm):0.5 (5)
• Electrolyte volume in the tab, cu. M -0,85
• Machine technological current source:
Current type: pulse,
Manufacturing current: pulse width, ms 1-10
Manufacturing current: pulse value,maximum, A - 4000
Voltage steps number:- 3
Voltage rms value, V – 12:18:24
• Power supply: Current type- alternating, three-phase
• Frequency, Hz -50
• Voltage, V -380
• Maximum consumed powerwhile the largestprocessing area, kW 40
• Overall dimensions (LxWxH), mm -1650x1850x2040
• Weight, kg - 2200, CAD/CAM LABORATORY EQUIPMENTS, educational cnc milling machines manufacturers, educational cnc LATHE machines manufacturers, Strength of Material Testing equipment supplier, mechanical engineering laboratory equipments suppliers, soil, bitumen, concrete testing, civil engineering laboratory equipments suppliers